

If at least one license dongle is configured, an additional License Device column is visible in the Order Information tab. For technical reasons (e.g. EtherCAT not in OP mode) there is no permanent connection to a TwinCAT 3 license dongle (see also: Determining the current status of a license dongle). Update the dongle status to ensure that TwinCAT 3 Engineering also accesses the dongle currently connected to the system and that the data displayed in the system is not from the last dongle to which a connection was established. In order to be able to use a license dongle as a License Device, it must be connected to the target system and configured in TwinCAT 3 (see also: Working with TwinCAT 3 license dongles). If you use an IPC from a manufacturer other than Beckhoff (TwinCAT 3 platform level >= 90), a TwinCAT 3 license dongle is always required for licensing TwinCAT 3. The manually set license is added to the automatically determined license and does not replace it. If you first disable automatic detection of the licenses required for the project, manually add a license detected as required and then re-enable automatic detection, this license is listed twice in the License Request File. If the checkbox is unchecked, you cannot deselect licenses required for the project. You can check the checkbox Disable automatic detection of required licenses for project to disable automatic detection of the licenses required for the project and select or deselect each license individually. If your licenses originate from two or more orders, you have to create a separate License Request File for each order (and the corresponding licenses). Select only licenses that belong to a common order number. On the Manage Licenses tab, manually change the list of licenses to be included in the License Request File. If you have added licenses manually, these are also listed here. On the Order Information tab in the lower part of the screen, you can see a list of licenses that TwinCAT has automatically determined on the basis of your project. 70 5.Open the TwinCAT 3 license manager by double-clicking on License in the SYSTEM subtree of your TwinCAT 3 project.


59ĥ.1.7 Command Recent Projects and Solutions. 58 5.1.4 Command Open Project from Target. 56 5.1.3 Command Project/Solution (Open Project/Solution). 40 4.2 Updating the TwinCAT 3 documentation. 40 4.1 Calling the TwinCAT 3 documentations. 37 3.2.6 Toggle between views and windows. 36 3.2.4 Arranging the menu bar and the toolbar. 33 3.1.1 Customizing text editor settings. File Info : application/pdf, 266 Pages, 5.45MB Document Document TC3 User Interface EN Manual | ENġ Foreword.
